Citation

Abstract

The performance of the solar-powered vapor-jet refrigeration scheme is compared with five selected working fluids: R-11, R-12, R-113, Butane and Water. These fluids were selected among those able to suit both a power cycle and a refrigeration cycle. The results indicated that water has the highest coefficient of performance and differs by a wide margin compared to the other compound organic fluids at all boiler and evaporator temperatures considered.

Details

Volume
42-44
Published
April 15, 1978
Pages
245–251
File Size
576.4 KB