Citation
Abstract
In early 1976 simultaneous one-way doppler demonstrations were performed on Pioneer 11. The data noise of the differenced one-way doppler as computed from the pseudo residuals is around 0.002 Hz, which is nearly an order of magnitude smaller than the one-way doppler noise and about the same as differenced two-way /three-way doppler noise. This report describes the demonstration results and discusses the applicability of differenced one-way radio metric data to spacecraft navigation.
Details
- Volume
- 42-45
- Published
- June 15, 1978
- Pages
- 104–110
- File Size