Vibration and noise levels in two of the DSN Deep Space Station (DSS) Operations Rooms have been an annoyance to personnel and are the suspected cause of tracking equipment failures. Measured noise levels were compared to Standard Noise Level Criteria curves. Precision instrumentation was used to measure noise and vibration levels in the rooms and equipment racks. Findings resulting from analysis of the measured data coupled with on-site noise reduction tests are discussed.