Citation
Abstract
Comparison of four scanning schemes including CONSCAN indicates that CONSCAN with signal cleanup and protection processes has the greatest merit in terms of accuracy, dependability and automatic unattended operation. Specific problem areas, error sources, and corrective measures are discussed.
Details
- Volume
- 42-64
- Published
- August 15, 1981
- Pages
- 116–122
- File Size