Citation

Abstract

The prototype Operational Time Sync (OTS) Microwave Subsystem has been redesigned to accommodate the change in operational frequency and to increase its power handling capability. The completed system has been successfully tested to 115 kW CW at 7150 MHz and is expected to operate at 150 kW CW, the design goal.

Details

Volume
VI
Published
December 15, 1971
Pages
165–167
File Size
378.5 KB