System operating noise temperatures and other calibration data of the S-band research operational (SRO) cone at DSS 13 and the tricone system at DSS 14 are reported for the period October 1, 1971 through January 31, 1972. During this reporting period the tricone system consisted of the polarization diversity S-band (PDS) cone, the S-band megawatt transmit (SMT) cone, and the multifrequency X- and K-band (MXK) cone. S-band calibration data for various configuration modes of the PDS and SMT cones are reported as well as X-band calibration data for the MXK cone.
Details
- Volume
- VIII
- Published
- April 15, 1972
- Pages
- 61–67
- File Size