Citation

Abstract

The complete statistical behavior of the random gain of a photomultiplier tube (PMT) has not previously yielded to exact analysis. In this paper a Markov diffusion model is used to determine an approximate probability density for the random gain. This approximate density preserves the correct second-order statistics and appears to be in reasonably good agreement with previously reported experimental data. The receiver operating curve for a pulse counter detector of PMT cathode emission events is analyzed using this density. The error performance of a simple binary direct detection optical communication system is also derived.

Details

Volume
42-68
Published
April 15, 1982
Pages
55–67
File Size